3.8 Mounting Considerations
Comdial engineers designed the FXT cabinet to match modern office equipment. Therefore it is not
necessary for installers to locate the FXT cabinet in a special equipment room. Available mounting
options include an equipment shelf that installers can attach to a wall and then secure to the cabinet
bottom or rollers that installers can attach to the bottom of the cabinet.
Regardless of whether you set the cabinet on a table, the optional equipment shelf, or the rollers, there
are several positioning considerations you must consider.
Always choose a secure and dry mounting location that has plenty of ventilation. Be sure the temperature
range of the location is within 32-122 degrees F (0-50 degrees C) and that the humidity is less than 90
percent, non-condensing.
Locate the equipment within four feet of a proper AC electrical outlet dedicated exclusively to this
equipment. The outlet must be a switchable 115 VAC 15 AMP circuit with a third-wire ground supplied to
a standard electrical outlet (NEMA 5-15R)
Locate the equipment within 25 feet of the TELCO/PBX jacks—this is an FCC requirement. A nominal
distance of seven feet is ideal.
Use a reliable earth ground—such as the ground bus in the AC power panel.
CAUTION
DO NOT STACK CABINETS!
General Description 3 – 9
General Description GCA40–215